Treadstone® R2 Sound Attenuating Mat

Click to View/Download

Downloadable PDF

Treadstone™ R2 Sound Attenuating Mat is a cylindrical studded membrane made of a mix of UV stabilized recycled polyolephines, laminated to a polypropylene fabric. The rigid studded technology of R2 delivers superior durability and enhanced acoustic performance in the most challenging of projects.

Treadstone™R2 is loose-laid over the substrate and then covered with a uniform thickness of an approved Treadstone™ Underlayment Product. Mechanical Fastening is not required, providing a system prole thickness as thin as 1.15” (29.2 mm).

  • In conjunction with 1” of Treadstone™ Underlayment, the installed system can reduce impact noise (IIC) up to 12 dB in wood framed assemblies. Refer to Treadstone™ Acoustical Design Guide for acoustical test performance, or contact Formulated Materials for specific test data.
  • Polypropylene barrier fabric • Low profile; .15” or 3.8mm • Excellent noise control performance with a spectrum of floor covering options.
  • Industry leading compression resistance
  • Because this system is embedded, noise problems are reduced, even when floor coverings are changed or replaced
  • UL listed in over 0 designs, for specific design or data contact us at info@formulatedmaterials.com.

Treadstone™R2 Sound Attenuating Mat in conjunction with an approved Treadstone™ Underlayment, is recommended and approved in;

  • Multi-Family Construction
    • Apartments
    • Hotels
    • Condominiums
  • Residential and Single Family • Commercial Ofce Space • Renovation of old wood frame or concrete structures

 

 FABRIC

 Raw Material   Polypropylene   

 Weight EN-1849-1 g/m2 75 oz/yd2 2.21±10%

 Thickness  mm 0.75 in 0.03±15%

 Width  m1.14 in 45 ±2%

 Tensile Strength (mean) EN 29073/3 N 115   ±15%

 Elongation at max load (mean) EN 29073/3 % 90   

 

 CORE

 Raw Material  Mx of Polyethylene and Polypropylene

 Weight g/m2 500 lb/ft2 0.1 ±10%

 Width m 1.08 ft 3.54 ±2%

 

 MECHANICAL RESISTANCE     

 Compression and Deflection  Compression res.  Residual Thickness 

  (kPa) (psf) time (mm)(in)

  2 41.8 0 3.90 0.15

  5 104.4 0 3.80 0.15

  5  104.4 1 week 3.73 0.15

  5  104.4 1 month 3.72 0.15

  5  104.4 3 months 3.70 0.15
 DIMENSIONS/PACKAGING      

 Weight EN965            g/m2 575 lb/ft2        0.12±2%

 Thickness EN964-1 mm 3.8 in 0.15 ±2%

 Adhesive tape for overlapping   butyl strip   

 Width with flap  m 1.14 in 45.0 ±2%

 Length  m 27.4 ft 90 ±2%

 Roll area  m2 31.2 ft2 340 ±4%

 Roll diameter  0 42.6 in 16.8 ±10%

 Roll weight  kg 17.5 lbs 37.6 ±10%

 Rolls per pallet  number       6 n 6 

SURFACE PREPARATION

Clean, remove all foreign matter from surface. Surface must be dry.

APPLICATION

Treadstone™ R2 Sound Attenuating Mat is to be installed by a licensed Treadstone™ Dealer. The building must be closed in with a minimum of 50 degrees F, maintained for a period of 5-7 days during and after the installation of Treadstone™ R2 and Treadstone™ Underlayment. R2 is loose laid on the suboor with seams tightly joined and fastened by peeling plastic lm from butyl strip of overlap ap, and pressing rmly to the adjoining R2. The perimeter of rooms, adjoining walls, all xed objects, and mechanical penetrations must be isolated with Treadstone™ Perimeter Isolation Strip.

STORAGE

Store in dry conditions.

  • Treadstone™ R2 is only one component of the oor ceiling assembly and overall noise reduction strategy. While using Treadstone™ R2 will improve the overall acoustics performance of the assembly, the exact amount or minimum performance cannot be guaranteed. Formulated Materials recommends contacting an acoustical consultant for recommendations regarding the acoustical performance of any and all projects.
  • To minimize risk of damage to the Treadstone™ Underlayment, installation of R2 and underlayment is recommended after drywall. For installation prior to drywall, contact Formulated Materials for recommendations.
  • Treadstone™ Underlayment thickness/compressive strength recommendations
    • Residential/Multifamily Construction: 1” (25.4mm) at 2,000 psi minimum
    • Light Commercial: 1” (25.4mm) at 3,000psi minimum

G230  G516  G524  G561  G577  G578  G579  G580  G581  G582  G587  G592

H502

J917  J919  J920  J924  J927  J931  J957 J958  J991  J994

L006  L201  L202  L206  L209 L210  L211  L212  L501  L502  L503  L504  L505  L506  L507  L508  L509  L510  L511  L512  L513  L514  L515  L516  L517  L518  L519  L520  L522  L523  L524  L525  L526  L527  L528  L529 L 530  L532  L533  L534  L535  L536  L537  L538  L539  L540  L541  L542 L543  L545  L546  L549  L550  L551 L552  L556  L557  L558  L560  L562  L563  L565  L570  L573  L574  L576  L577  L579  L581  L583  L585  L587  L588  L589  L590  L592  L593

M500  M502  M503  M504  M506  M508  M511  M512  M513  M515  M517  M519  M530  M531  M535  M536